Sr. Substation Automation and Protection Engineer
Siemens
This job is no longer accepting applications
See open jobs at Siemens.See open jobs similar to "Sr. Substation Automation and Protection Engineer" Discover Technata.Job Description
Job ID
Company
Organization
Job Family
Experience Level
Full Time / Part Time
Contract Type
Company: Siemens Industry, Inc.
Location: 7000 Siemens Road, Wendell, North Carolina 27591
Position Title: Sr. Substation Automation and Protection Engineer
Hours: Monday – Friday, 8:00 am to 5:00 pm, 40 Hours/ Week
Summary of Duties: Design, implement, and maintain protective relay systems and associated equipment for power systems. Prepare Factory & Site Acceptance Test (FAT & SAT) procedures for protection systems projects. Prepare Test Set (Omicron, Doble, etc...) routines for various protection applications. Configure and test relays for protection and controls schemes of substations systems. Collaborate with a team of professionals to develop protection schemes that meet industry standards and customer requirements. Be a technical leader in projects or lead other team members in project activities. Be one of our primary customer interfaces, including trouble shooting and commissioning support. Provide technical support throughout the project lifecycle, including design, implementation, and commissioning phases. 75% Travel within the US and occasionally to our factories in Mexico and Germany.
Qualifications: The position requires a Bachelor’s degree or foreign equivalent in Electrical Engineering, or a related field and Six (6) years of experience in job offered or as a Power Systems Engineer, Test Engineer, or an acceptable alternate occupation. Alternate accepted requirements Master’s in Electrical Engineering, or a related field and Four (4) years’ experience. The position requires experience in power systems protection engineering field (Six (6) years’ experience with a Bachelor’s degree or 4 years’ experience with a Master’s Degree). Position requires experience with the following: Ability to read and fully understand DC and AC schematics, three- and one-line diagrams for Medium and/or High Voltage substations systems; Knowledge of Siemens, GE, SEL or ABB relay products and associated software; Applied knowledge of Medium Voltage Protection (eg; Overcurrent / Over-Undervoltage; Transformer Differential ;Motor Protection; High and Low Impedance Busbar Differential; Generator Protection; MV transfer schemes and reverse interlocking schemes); Communication Network Technologies, including Design, Configuration, and troubleshooting of ethernet switches for protection applications such as IEC-61850 GOOSE applications; experience with Siemens protection engineering software such as DIGSI 4 and DIGSI 5, IEC61850 System Configurator, SIGRA, SIPROTEC Tools and the ability to use those to implement protection systems in the US according to customers specifications and standards; Implementation of logics using CFC based on Logic Diagrams or Functional Design Specification; Ability to understand protection settings documentation provided by SCAFF study and implement and test those using Siemens Relays.
Siemens is an Equal Opportunity and Affirmative Action Employer encouraging diversity in the workplace. All qualified applicants will receive consideration for employment without regard to their race, color, creed, religion, national origin, citizenship status, ancestry, sex, age, physical or mental disability unrelated to ability, marital status, family responsibilities, pregnancy, genetic information, sexual orientation, gender expression, gender identity, transgender, sex stereotyping, order of protection status, protected veteran or military status, or an unfavorable discharge from military service, and other categories protected by federal, state or local law.
Reasonable Accommodations
If you require a reasonable accommodation in completing a job application, interviewing, completing any pre-employment testing, or otherwise participating in the employee selection process, please fill out the accommodations form by clicking on this link Accommodation for disability form. If you’re unable to complete the form, you can reach out to our AskHR team for support at 1-866-743-6367. Please note our AskHR representatives do not have visibility of application or interview status.
EEO is the Law
Applicants and employees are protected under Federal law from discrimination. To learn more, Click here.
Pay Transparency Non-Discrimination Provision
Siemens follows Executive Order 11246, including the Pay Transparency Nondiscrimination Provision. To learn more, Click here.
California Privacy Notice
California residents have the right to receive additional notices about their personal information. To learn more, click here.
Qualified applications with arrest or conviction records will be considered for employment in accordance with applicable local and state laws.
This job is no longer accepting applications
See open jobs at Siemens.See open jobs similar to "Sr. Substation Automation and Protection Engineer" Discover Technata.